Step 1: Knock the unopened drug identification test ampoule several times against a hard surface, so the granules which may be sticking to the inside of the ampoule wall will fall downwards.
Step 2: Take the top of the drug identification test ampoule between the thumb and index finger and snap off the top with the ampoule breaker.
Step 3: Use the spatula to insert the suspect material into the drug identification ampoule.
Step 4: For suspect samples in liquid form such as GHB, we advise to use the round end of the supplied spatula or otherwise use a pipette and insert one drop into the drug identification test ampoule.
Step 5: With the MMC LSD / Cannabis and Ketamine Test, the plastic lid contains a catalyst pearl which, once the material to be tested is inserted in the drug identification test ampoule, must be mixed using the round tip of the spatula.
Step 6: Attention! If the ball in the cap sticks against the side, please use a spatula to take it out and, put it in the drug identification test ampoule and mix it. Place the plastic cap on top of the ampoule.
Step 7: Compare the colour from the reagent granulate with the colour line printed on the ampoule.
Step 8: Compare the colour from the reagent granulate with the colour line printed on the ampoule.